404 WIN-PAK User Guide
1 The Name list displays the output points avail-
able on the 2-reader board, and shows them as
active (with the check box selected), with No
ADV.
The PRO-2200 Series Dual Reader Module has
six output points, and all are displayed in the list
box at the top of the Outputs window [the PRO-
2200 Series Single Reader Module has one
output point]. Remember, any output point you
intend to use as a control point will require an
ADV.
WIN-PAK sets some output points as active.
The default settings [typically 1 and 3] may vary
depending upon whether or not you have chosen
the anti-passback option.
NOTE: Output points 1 and 3 are reserved by WIN-
PAK for use with door interlocks, and therefore cannot
be assigned an ADV.
2 Use the Time Zone drop-down list to attach a
time zone to an output point. For example, to
shunt [deactivate] an output point during a
particular time zone, select that time zone from
the list. The Time Zone defaults to None.
3 Enter a value in the Pulse Time field to set the
amount of time that the output point is ener-
gized when triggered. The field defaults to zero,
but can be set from 0 to 63 seconds, 0 to 63
minutes, 0 to 63 hours.
4 The Output Inverter field [which defaults to
Normal] can be changed to Inverted.