383
7 The Pair Reader area of the window is only
active if one of the Paired options is selected as
the Access Configuration. Pair Reader options
allow you to establish an interlock of sorts, by
selecting an SIO Board and a Reader.
8 Anti-Passback discourages users from entering
with others, without using their own cards. Cards
must be used at a designated In reader, then at a
designated Out reader before the card can be
read in again. Consult your local fire regulations
before using Anti-Passback.
9 Direction allows you to specify if the reader is in
or out. [Defaults to None.]
10 The Processing Mode indicates whether the
reader, the card, or the panel will remember the
sequencing, and whether or not access is granted
if a violation occurs. The default is None.
Following is a list of Processing Modes and results.
Processing Mode and Results
None
No Anti-Passback in effect.
Soft
Upon an Anti-Passback violation, the card is still granted
access and reports [in the Alarm View] either:
Anti-Passback violation, door used -or- Anti-Passback
violation, door not used. Example: A card is swiped for
the first time at an Anti-Passback reader. The card is
valid and is granted access [Alarm View shows "Valid
card, door used"0]. If the cardholder decides not to open
the door and go through, the second time their card is
swiped at the same Anti-Passback reader, the card is
again granted access, but this time Alarm View shows
"Anti-Passback violation, door used."
Programming